FIT-FT0#
FT0: General#
All QC plots are generated in 5 min. cycles. The histogram contents are reseted after each cycle. Please wait at least 10 min. from the start of the RUN to judge about the quality of collected data.
If a non-critical (i.e. expendable) QC task fails, please add a bookkeeping entry about it.
There will be many empty channels in FT0 plots for COSMICS. This can be safely ignored
FT0: Amplitude vs channel#
[QC on EPN/QC nodes - plot integrated over the QC cycle]
Charge amplitude distribution vs channel ID [0-207]. It should be non-empty.
Units: Charge is expressed in ADC channels.
Actions:
- if one or more empty channels (crosscheck known-issues file) - call FIT-on-call.
FT0: Time vs channel#
[QC on EPN/QC nodes - plot integrated over the QC cycle]
The time distribution vs channel ID [0-207]. It should be non-empty.
Units: Time is expressed in TDC channels, channel = 13 ps.
Actions:
- if one or more empty channels (crosscheck known-issues file) - call FIT-on-call.
Known issues#
- channels 60-63 (FT0A side) are OFF in PHYSICS and COSMICS runs
- channels 139 and 176-179 (FT0C side) are OFF in PHYSICS and COSMICS runs