Skip to content

TRG

Trigger BC comparison CTP - LHC filling scheme#

Green: good quality Red: bad quality
BC Good BC Bad

Quality#

Null quality#

LHC filling scheme is not read from CCDB.

Bad quality: Empty BC where nothing is expected > threshold#

Zoom plot near the indicated BC. In case a reported BC bin content is much lower then filled BCs, add BK entry and DO NOT call CTP on-call. In case a reported BC bin content is comparable to filled BC, call CTP on-call.

Medium quality: filled BC < threshold#

Call ctp on-call.

In case of wrongly filled LHC both conditions would happen, i.e. there are empty BC bins with content > threshold and filled BC bins with content < threshold.#

Input rate and ratio#

Green: good quality Red: bad quality Yellow: medium quality
Inputs Good Inputs Bad Inputs Medium

Bad quality:#

Rate change > 3 $\sqrt{\mathrm{rate}}$

Medium quality:#

Rate cange > 2 $\sqrt{\mathrm{rate}}$

Ignore the EMC and DMC inputs during the interventions by EMC on-call.#

Trigger BC comparison CTP - EMC#

Green: good quality Red: bad quality
BCDistGood BCDistBad

In case the shift is different from 0 call CTP on-call

Missing bunch train CTP#

BCDistGood