PHS KNOWN ISSUES#

  • COSMIC, TECHNICAL, PHYSICS_PP runs Cell HG occupancy, mod[1-4]: white horizontal stripes can be seen which differs from the reference plots. QC shifter can ignore these patterns, because they are caused by dynamic FEE mask which is changed by the PHOS experts without prior notice. Only completely empty plots should be reported by the QC shifter to PHOS/CPV on-call
  • COSMIC, TECHNICAL, PHYSICS_PP runs Cell HG occupancy, mod1 shows missing data in the area x=(32,47);z=(0,27) since end of March 2023. This is a known issue and is being investigated by PHS experts. No need to report it in the QC EOS reports and no calls to PHS/CPV shifters are needed.
  • COSMIC, TECHNICAL, PHYSICS_PP runsSometimes QC shifters report on the error message in EPN infoLogger: Trailer decoding error: Last RCU trailer word not found. These errors are persistent, they appear in all COSMIC, TECHNICAL, PHYSICS runs since the beginning of Run3, and caused by a bug in SRU firmware. All these errors should be ignored.